Determine minimum clearance (through air) and creepage (over a surface) distances per IEC 60664-1 methodology, accounting for pollution degree, material group (CTI) and altitude — from sea level up to 50,000 ft — with a Paschen's Law first-principles cross-check. Every calculation step is shown below with your numbers substituted in.
New to IEC 60664-1? Read the guide: Creepage & Clearance: How IEC 60664-1 Sets Insulation Distances — a plain-language explainer of the standard behind this calculator.
Clearance uses IEC 60664-1 Table F.2 (verified against the standard's full text), with a choice of Case A (inhomogeneous field, always usable) or Case B (homogeneous field, smaller clearances but requires geometry designed for a uniform field and verification by voltage-withstand test), plus the table's own footnoted pollution-degree floors (PD2 ≥ 0.2 mm, PD3 ≥ 0.8 mm, PD4 ≥ 1.6 mm — small gaps can be bridged completely by particles/condensation regardless of the voltage a gap otherwise has to withstand). Clearance is driven directly by the working voltage (and separately by the working voltage to chassis), altitude-corrected — this tool does not step the working voltage up through an overvoltage category / rated impulse withstand voltage (IEC 60664-1 Table F.1) first, which is a deliberate simplification that will understate required clearance for circuits exposed to significant transient overvoltages (e.g. direct mains connection) — add your own margin for those. Creepage uses the IEC 60664-1 CTI/pollution-degree methodology (subclause 2.7.1.3) as tabulated in Table F.4, assuming functional insulation throughout (this tool does not model basic/supplementary/reinforced insulation separately). Both creepage and clearance are now power-law interpolated between the standard's tabulated voltage points (rather than taking the next-higher band's more conservative value), since these tables approximate a power law, not a straight line, or a step function. Altitude correction (IEC 60664-1 Table F.10 / Table A.2) is applied only to clearance — cross-checked against standard-atmosphere barometric pressure, and against Paschen's Law directly. Paschen's Law assumes an idealised uniform field between clean electrodes; real-world breakdown voltage is typically lower due to field non-uniformity, surface roughness and humidity — treat it as a physics sanity check, not a substitute for the standard's tested margins. Pollution degree 4 has no creepage table value (enclosure/coating design required) but clearance still computes via its footnoted floor. This tool supports engineering estimation — verify exact values against the current official IEC 60664-1 text, and any applicable product standard, before certification use.
Voltage input mode: both voltage fields can be entered as RMS or as a peak/withstand value — switching modes only changes how the numbers you type are interpreted (Vrms = Vpeak/√2, assuming a sinusoidal waveform); every downstream calculation still uses RMS internally, matching Table F.4's own basis. For a DC or non-sinusoidal withstand rating, enter RMS directly if you know it.
Rib / groove creepage reduction (Premium): a rib (raised barrier) or groove (recessed channel) molded or cut into the insulation surface lets the required creepage distance be met within a smaller flat footprint, since the standard's measurement rule traces the creepage path up-and-over (or down-and-across) the feature rather than straight across it. A feature narrower than IEC 60664-1's pollution-degree-dependent minimum width — 0.25mm at PD1, 1.0mm at PD2, 1.5mm at PD3 (reproduced from the standard's own table, cross-checked against Texas Instruments' "Demystifying Clearance and Creepage Distance for High-Voltage End Equipment" application note, which cites and quotes the same IEC 60664-1 table) — is "bridged" in the standard's measurement: the path is measured straight across as if the feature weren't there, since contamination can span a gap that narrow, giving zero credit. A feature meeting the minimum width credits twice its height as additional creepage path length — the standard engineering approximation for a simple rectangular rib/groove profile (the path travels up one face and down the other, or vice versa), not a literal reproduction of the standard's full set of measurement figures for angled or rounded contours, uncemented joints, or multiple ribs in series, which this tool does not attempt to model.
Validated: checked that the calculator reproduces the standard's own tabulated points exactly at several spot checks (e.g. 1.0 kV Case A → 0.15 mm clearance; 400 V/PD2/Group I → 2.0 mm creepage; 250 V/PD2/Group IIIb → 2.5 mm creepage — all widely-cited reference figures), and that the power-law interpolation between tabulated points was independently re-derived from the documented formula and matches the calculator's output to 5+ significant figures at a non-tabulated voltage (0.7 kV → 0.07889 mm both ways). The rib/groove minimum-width table (0.25/1.0/1.5mm) exactly reproduces the TI application note's own published table; the bridging rule (below minimum → zero credit) and the 2× height credit rule were checked against hand-worked cases including the exact minimum-width boundary (width equal to, not just above, the minimum still counts).