1Electrical parameters
Drives both creepage and clearance directly — the highest voltage actually across the insulation.
Defaults to 50% of working voltage — edit to override.
Applied as a margin on top of the standard's calculated minimum distances (default 20%).
Case A is the safe default usable for any geometry; Case B needs a uniform-field design verified by test.
2Environment
PD4 has no creepage table value (IEC 60664-1 4.6.3) — requires enclosure/coating design; clearance still computes with its footnoted 1.6 mm floor.
Group IIIb (100 ≤ CTI < 175). IIIb is the conservative default for unknown/general-purpose plastics.
CTI per IEC 60112. If unknown, use Group IIIb.
No correction below 2000 m (6562 ft) — that is the standard's native reference condition. Correction applies to clearance only; creepage (a surface-tracking property) is not altitude-dependent.
Reference tables

Required distances (including the 20% factor of safety) at your current working voltage and HV-to-chassis voltage, across every Material Group / Case × Pollution Degree combination — the highlighted cell matches your current selection.

Creepage @ Working Voltage (300 V)
PD1PD2PD3
I0.83mm1.80mm4.53mm
II0.83mm2.51mm5.09mm
IIIa0.83mm3.60mm5.66mm
IIIb0.83mm3.60mm5.66mm
Creepage @ HV to Chassis (150 V)
PD1PD2PD3
I0.37mm0.94mm2.37mm
II0.37mm1.30mm2.61mm
IIIa0.37mm1.89mm2.97mm
IIIb0.37mm1.89mm2.97mm
Clearance @ Working Voltage (0.3 kV, altitude-adjusted)
PD1PD2PD3
Case A0.01mm0.24mm0.96mm
Case B0.01mm0.24mm0.96mm
Clearance @ HV to Chassis (0.15 kV, altitude-adjusted)
PD1PD2PD3
Case A0.00mm0.24mm0.96mm
Case B0.00mm0.24mm0.96mm
Paschen's Law cross-checkconsistent

First-principles physics, independent of the IEC table: air's dielectric breakdown voltage depends on the pressure × gap product (p·d). At 5,000 ft the local pressure is 84.56 kPa (vs 101.33 kPa at sea level) — for a 0.24 mm gap, p·d = 2.029 kPa·cm, well above the Paschen minimum (0.111 kPa·cm), so breakdown voltage still falls monotonically as altitude increases — the IEC table's assumption holds throughout this range.

Breakdown voltage at this gap
1,424V
Min. gap for working voltage
0.005mm
requiredPaschen min (304 V)your design02000400060008000V0.050.10.20.51251020p·d (kPa·cm, log scale)
Rib / groove creepage reduction

A rib (raised barrier) or groove (recessed channel) of adequate width lets the standard's required creepage distance be achieved within a smaller flat-surface footprint — the creepage path is measured up-and-over (or down-and-across) the feature rather than straight across it, adding roughly twice its height to the path.

Minimum width at PD2: 1 mm. ✓ Meets the minimum — credits 4 mm of additional creepage path (2×H).
Required flat-surface footprint
Without rib/grooveWith rib/groove
Working voltage3.60mm0.00mm
HV to chassis1.89mm0.00mm
livechassisW = 1.50 mmH = 2.00 mmCreepage path traced by the standard's measurement rule
Reference & assumptions

New to IEC 60664-1? Read the guide: Creepage & Clearance: How IEC 60664-1 Sets Insulation Distances — a plain-language explainer of the standard behind this calculator.

Clearance uses IEC 60664-1 Table F.2 (verified against the standard's full text), with a choice of Case A (inhomogeneous field, always usable) or Case B (homogeneous field, smaller clearances but requires geometry designed for a uniform field and verification by voltage-withstand test), plus the table's own footnoted pollution-degree floors (PD2 ≥ 0.2 mm, PD3 ≥ 0.8 mm, PD4 ≥ 1.6 mm — small gaps can be bridged completely by particles/condensation regardless of the voltage a gap otherwise has to withstand). Clearance is driven directly by the working voltage (and separately by the working voltage to chassis), altitude-corrected — this tool does not step the working voltage up through an overvoltage category / rated impulse withstand voltage (IEC 60664-1 Table F.1) first, which is a deliberate simplification that will understate required clearance for circuits exposed to significant transient overvoltages (e.g. direct mains connection) — add your own margin for those. Creepage uses the IEC 60664-1 CTI/pollution-degree methodology (subclause 2.7.1.3) as tabulated in Table F.4, assuming functional insulation throughout (this tool does not model basic/supplementary/reinforced insulation separately). Both creepage and clearance are now power-law interpolated between the standard's tabulated voltage points (rather than taking the next-higher band's more conservative value), since these tables approximate a power law, not a straight line, or a step function. Altitude correction (IEC 60664-1 Table F.10 / Table A.2) is applied only to clearance — cross-checked against standard-atmosphere barometric pressure, and against Paschen's Law directly. Paschen's Law assumes an idealised uniform field between clean electrodes; real-world breakdown voltage is typically lower due to field non-uniformity, surface roughness and humidity — treat it as a physics sanity check, not a substitute for the standard's tested margins. Pollution degree 4 has no creepage table value (enclosure/coating design required) but clearance still computes via its footnoted floor. This tool supports engineering estimation — verify exact values against the current official IEC 60664-1 text, and any applicable product standard, before certification use.

Voltage input mode: both voltage fields can be entered as RMS or as a peak/withstand value — switching modes only changes how the numbers you type are interpreted (Vrms = Vpeak/√2, assuming a sinusoidal waveform); every downstream calculation still uses RMS internally, matching Table F.4's own basis. For a DC or non-sinusoidal withstand rating, enter RMS directly if you know it.

Rib / groove creepage reduction (Premium): a rib (raised barrier) or groove (recessed channel) molded or cut into the insulation surface lets the required creepage distance be met within a smaller flat footprint, since the standard's measurement rule traces the creepage path up-and-over (or down-and-across) the feature rather than straight across it. A feature narrower than IEC 60664-1's pollution-degree-dependent minimum width — 0.25mm at PD1, 1.0mm at PD2, 1.5mm at PD3 (reproduced from the standard's own table, cross-checked against Texas Instruments' "Demystifying Clearance and Creepage Distance for High-Voltage End Equipment" application note, which cites and quotes the same IEC 60664-1 table) — is "bridged" in the standard's measurement: the path is measured straight across as if the feature weren't there, since contamination can span a gap that narrow, giving zero credit. A feature meeting the minimum width credits twice its height as additional creepage path length — the standard engineering approximation for a simple rectangular rib/groove profile (the path travels up one face and down the other, or vice versa), not a literal reproduction of the standard's full set of measurement figures for angled or rounded contours, uncemented joints, or multiple ribs in series, which this tool does not attempt to model.

Validated: checked that the calculator reproduces the standard's own tabulated points exactly at several spot checks (e.g. 1.0 kV Case A → 0.15 mm clearance; 400 V/PD2/Group I → 2.0 mm creepage; 250 V/PD2/Group IIIb → 2.5 mm creepage — all widely-cited reference figures), and that the power-law interpolation between tabulated points was independently re-derived from the documented formula and matches the calculator's output to 5+ significant figures at a non-tabulated voltage (0.7 kV → 0.07889 mm both ways). The rib/groove minimum-width table (0.25/1.0/1.5mm) exactly reproduces the TI application note's own published table; the bridging rule (below minimum → zero credit) and the 2× height credit rule were checked against hand-worked cases including the exact minimum-width boundary (width equal to, not just above, the minimum still counts).

Calculation steps
1. Altitude correction factor (IEC 60664-1 Table F.10)
k = f(altitude), linearly interpolated between tabulated points; k = 1.0 below 2000 m
Altitude = 5,000 ft = 1,524 m
k = 1
2. Altitude-adjusted voltage for clearance (working voltage used directly — no overvoltage-category step-up)
V_clearance = working voltage × k
Working voltage: 300 V × 1 = 300 V. HV to chassis: 150 V × 1 = 150 V
0.3 kV (working) / 0.15 kV (HV to chassis)
3. Required clearance (IEC 60664-1 Table F.2, Case A — inhomogeneous field, PD2 floor) + safety factor
Clearance = max(f(V)^b (ratio-based), pollution-degree floor) × (1 + FoS)
Working voltage: base 0.2 mm (PD floor applied), with 20% margin = 0.24 mm. HV to chassis: base 0.2 mm (PD floor applied), with margin = 0.24 mm
4. Required creepage distance (IEC 60664-1 Table F.4, functional insulation) + safety factor
Creepage = f(working voltage, pollution degree, material group)^b (power-law interpolated between tabulated voltage bands) × (1 + FoS)
PD2, Group IIIb (100 ≤ CTI < 175)
Working voltage (300 V): base 3 mm, with margin = 3.6 mm. HV to chassis (150 V): base 1.573 mm, with margin = 1.888 mm
5. Paschen's Law cross-check
V_b = B·(p·d) / [ln(A·(p·d)) − ln(ln(1 + 1/γ))], A=113/(kPa·cm), B=2740 V/(kPa·cm), γ=0.01
p = 84.56 kPa at 5,000 ft, d = 0.24 mm → p·d = 2.029 kPa·cm
V_b = 1,424 V vs working voltage 300 V — consistent with the design
6. Rib / groove creepage reduction (IEC 60664-1)
Credit = widthOk ? 2·H : 0 (widthOk = W ≥ minimum-width(PD)); footprint = max(0, required creepage − credit)
H = 2 mm, W = 1.5 mm, minimum width at PD2 = 1 mm
Credit = 4 mm. Footprint (working voltage) = 0 mm, (HV to chassis) = 0 mm